A service call on a hotel kitchen’s Manitowoc, one with an Indigo NXT controller. Before gauges go anywhere near it, the first stop is the screen.

The Indigo NXT has a live inputs page. In one screen it tells you what the machine can see: the curtain switch, the high-pressure cutout, the ice thickness probe, the water level probes. This shot is eleven seconds into harvest. Curtain closed, pressure switch closed, water probes not sensing because the sump has just dumped. That’s what harvest should look like.

The value of that page is that it separates the machine can’t see it from the machine sees it and won’t act. A curtain switch that reads open with the curtain shut is a quick fix. The same symptom chased with gauges is an hour.

With the inputs looking right, the next place to look was the water side, starting with the water level probe in the sump.

Modern ice machines diagnose themselves better than most people expect. You just have to know which screen to look at, and what normal looks like at each step of the cycle.

If it heats or cools, we handle it. 📞 718-802-1700

Service: Ice machine service.

More insights